1.
Gerodontology ; 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38563231

RESUMO

OBJECTIVE: To evaluate the touch perception threshold of the alveolar mucosa and quality of life of edentulous patients before (T0) and 30 days after (T1) the insertion of new complete dentures. BACKGROUND: Touch perception is important so that edentulous patients can detect the position of complete dentures in their mouth. MATERIALS AND METHODS: This study included 32 complete denture wearers with good oral and systemic health and no temporomandibular disorders for at least 5 years. At each time point (T0 and T1), two tests were performed (touch perception threshold and quality-of-life scale). The touch perception threshold (Von Frey or Semmes-Weinstein test) was assessed using nylon monofilaments on the regions of the alveolar mucosa of the maxilla and mandible. The Oral Health Impact Profile for edentulous individuals (OHIP-EDENT) was administered to evaluate oral health-related quality of life. RESULTS: In the maxilla and mandible, the touch perception thresholds for all regions of the alveolar mucosa were significantly lower at T1 than at T0. The OHIP-EDENT mean scores showed that the overall quality of life was significantly better at T1 (3.6) than at T0 (4.7), and a significant improvement in quality of life was observed in all domains of the OHIP-EDENT at T1. For touch perception threshold, effect sizes ranged from 0.4 to 0.8; and for quality of life, effect sizes ranged from 0.4 to 1.0. CONCLUSIONS: New complete dentures reduced the touch perception threshold of the alveolar mucosa of both edentulous arches and improved individuals' quality of life.

2.
J Prosthet Dent ; 2023 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-37865553

RESUMO

STATEMENT OF PROBLEM: With the growing use of digital scanning, an evaluation of the clinical impact of digital scans versus conventional impressions in complete arch implant-supported prostheses is needed. However, systematic reviews on this subject are lacking. PURPOSE: The purpose of this systematic review was to evaluate the scanning and impression times and the radiographic marginal bone loss over time associated with digital scans and conventional impressions for complete arch implant-supported fixed prostheses. MATERIAL AND METHODS: The search was performed in MEDLINE/PubMed, SCOPUS, EMBASE, and Web of Science. Only randomized clinical trials (RCTs) comparing digital scans and conventional impressions for complete arch prostheses were included in the review. The scan and impression times and marginal bone loss were analyzed through random effects meta-analysis. RESULTS: Six RCTs were included. The meta-analysis was conducted by using a standardized mean difference (MD) and indicated a statistically significant reduction in time for the digital scan group compared with the conventional group (MD 10.01 [7.46, 12.55], P<.001, I²=80%). The fact that digital scans were used did not lead to significant differences in radiographic marginal bone loss compared with conventional impressions after 6 months (MD -0.03 [-0.14, 0.08], P=.58, I²=0%), after 12 months (MD -0.06 [-0.24, 0.12], P=.12, I²=45%), and after 24 months (MD -0.12 [-0.32, 0.09], P=.28, I²=58%). CONCLUSIONS: Digital scans significantly reduced the time required compared with conventional impressions for complete arch implant-supported prostheses. Nevertheless, additional studies with more consistent methodologies are needed for confirmation. No significant differences were found in radiographic marginal bone loss between treatments performed with digital scans and conventional impressions.

3.
J Prosthet Dent ; 2023 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-37793953

RESUMO

STATEMENT OF PROBLEM: Implant-supported fixed dental prostheses can be cement- or screw-retained on the implant or abutment, with advantages and disadvantages for each method. Cemented prostheses have been associated with peri-implant disease because cement remnants act as a reservoir for bacteria and hinder biofilm control. However, contrasting evidence has been presented regarding this association based on studies with varying designs, and a systematic review and meta-analysis is required. PURPOSE: The purpose of this systematic review and meta-analysis was to answer the focused question: In patients who received implant-supported prostheses, is the incidence of peri-implant diseases higher in cemented implant-supported prostheses than in screw-retained ones? MATERIAL AND METHODS: The search was conducted using the National Library of Medicine (MEDLINE-PubMed), SCOPUS, EMBASE, and ISI Web of Science databases. Randomized clinical trials (RCTs) that assessed the incidence of peri-implant disease in cement- and screw-retained prostheses were included. Two authors independently screened the titles and abstracts, and analyzed the full texts, extracted data, and assessed the risk of bias. The findings were summarized using meta-analyses with random effects, and the level of certainty of the evidence was determined using the grading of recommendations, assessments, development, and evaluations (GRADE) approach. RESULTS: The search yielded 4455 articles that met the inclusion criteria based on the title and/or abstract selection. A total of 6 RCTs were included for analysis. The meta-analysis revealed no significant difference between cement- and screw-retained prostheses for the risk of peri-implant mucositis (RR: 1.36, 95% CI: 0.42-4.38, P=.61). Similarly, no significant difference was observed between cement- and screw-retained prostheses for the incidence of peri-implantitis (RR: 1.00, 95% CI: 0.23-4.31, P=1.00). CONCLUSIONS: Moderate certainty evidence suggests that cement- and screw-retained prostheses present a similar risk for peri-implant mucositis and peri-implantitis.

4.
Quintessence Int ; 54(7): 536-547, 2023 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-37013667

RESUMO

OBJECTIVE: This pilot, prospective interventional study aimed to analyze the influence of supracrestal tissue height when using the one abutment-one time concept at the time of implant placement, on peri-implant hard and soft tissue remodeling in esthetic areas. The definitive crown was placed 7 days later. METHOD AND MATERIALS: Facial mucosal margin position, mesial and distal papilla levels, and mesial and distal marginal bone loss were assessed after 7 days (placement of the definitive crown), and 1, 2, 3, 6, and 12 months after implant placement. Patients were classified according to the supracrestal tissue height as thin (< 3 mm) and thick (≥ 3 mm). RESULTS: Fifteen patients fulfilled the eligibility criteria and were included in the study. Eight presented a thick supracrestal tissue height and seven a thin supracrestal tissue height. After 12 months, the implant success rate was 100%. The mean recession at the facial mucosal margin position was -0.47 ± 0.57 mm and -0.19 ± 0.41 mm in thin and thick groups, respectively (P = .29). The mean mesial papilla level recession was -0.19 ± 0.06 mm in the thin group and -0.01 ± 0.07 mm in the thick group (P < .01), and the mean distal papilla level recession was -0.15 ± 0.09 mm in the thin group and 0.00 ± 0.15 mm in the thick group (P < .05). The mean bone loss was -0.21 ± 0.18 mm and -0.04 ± 0.14 mm in the thin and thick groups, respectively (P < .05). CONCLUSION: Single maxillary anterior implants with thin supracrestal tissue height (< 3 mm) at the time of implant placement had greater bone loss and papillary recession than implants with a thick soft tissue height (≥ 3 mm), even when using the one abutment-one time concept.


Assuntos
Implantes Dentários para Um Único Dente , Implantes Dentários , Humanos , Estudos Prospectivos , Estética Dentária , Implantação Dentária Endóssea/métodos , Maxila/cirurgia , Resultado do Tratamento
5.
J Clin Exp Dent ; 15(1): e23-e31, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36755685

RESUMO

Background: The aim of this study was to verify if there is a relationship between self-reported pain, PPT (pressure pain threshold) of the masseter, temporal and sternocleidomastoid muscles, pain catastrophizing and quality of life in patients with TMD (temporomandibular disorder) of muscular origin. Material and Methods: Ninety-seven patients with muscular TMD (TMD group) and 97 asymptomatic (control group) were included in the study. The evaluation methods used were: 1) Self-reported pain was assessed using the Visual Analogue Scale (VAS) for questions 7, 8 and 9 of the RDC/TMD Axis I questionnaire; 2) The PPT assessment was performed using a digital algometer on the masseter, temporal, and sternocleidomastoid muscles (both sides); 3) Pain catastrophizing was assessed using the PCS (Pain Catastrophizing Scale); and 4) Oral health-related quality of life was assessed using the OHIP-14 (Oral Healthy Impact Profile-14). Data were submitted to Spearman correlation and logistic regression (p<0.05). Results: There were significant positive correlations between self-reported pain (VAS-Q7, VAS-Q8 and VAS-Q9), pain catastrophizing (PCS-Helplessness, PCS-Magnification, PCS-Rumination and PCS-Total) and quality of life (OHIP-14) (p<0.05). There was a significant negative correlation of self-reported pain (VAS-Q8) with PPT of the temporal (left) and sternocleidomastoid (both sides) (p<0.05). The rumination and magnification domains increased the chance of high self-reported pain in all situations (VAS-Q7, VAS-Q8 and VAS-Q9) (p<0.05). The helplessness domain only increased the chance of high self-reported pain for VAS-Q8 (p<0.05). The presence of TMD of muscular origin, high self-reported pain (VAS-Q7) or pain catastrophizing increased the chance of a low quality of life in relation to the control group (p<0.05). In addition, the reduction in sternocleidomastoid PPT increased the chance of poor quality of life (p<0.05). Key words:Myofascial pain syndromes, pain catastrophizing, myalgia, quality of life, surveys and questionnaires, temporomandibular joint disorders.

6.
J Prosthodont ; 32(6): 497-504, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36573906

RESUMO

PURPOSE: To assess the reproducibility of four different centric relation (CR) recording techniques, and time spent performing each technique in edentulous individuals. MATERIALS AND METHODS: Four techniques were assessed: extraoral gothic arch (EOGA) tracing, intraoral gothic arch (IOGA) tracing, deglutition (D), and frontal manipulation with tongue elevation (FMTE). Twelve subjects participated in the study; four technique records were performed on each volunteer by the same operator. Each record was repeated three times, in the same period of the day, with a 30 min interval between each technique. The reproducibility of each technique was assessed by the tri-dimensional displacement of the position of the condylar housing (mandible condyle) to the wall of the condylar guide (glenoid cavity) in the semi-adjustable articulator (anteroposterior, mediolateral, and superior-inferior). The time spent on each technique was timed in seconds (from the beginning of each technique until the wax occlusion fixation). The analysis of variance (ANOVA) and the Tukey test were performed for anteroposterior displacement (two-way) and for time spent on CT recording techniques (one-way) (α < 0.05). Regarding mediolateral and superior-inferior displacements, the nonparametric Kruskal-Wallis was performed for the comparison between recording methods, whereas the Mann-Whitney test was performed for the comparison between sides (α < 0.05). RESULTS: The factor recording technique interfered with the anteroposterior displacement (ANOVA: α < 0.001; F = 11.396). The technique D (right side: 3.78 ± 0.69 mm; left side: 3.45 ± 0.74 mm) showed a statistically significant difference compared to the other techniques (EOGA: right side: 3.00 ± 0.00 mm; left side: 3.00 ± 0.00 mm; FMTE: right side: 2.81 ± 0.52 mm; left side: 2.82 ± 0.79 mm; IOGA: right side: 2.90 ± 0.65 mm; left side: 3.12 ± 0.44 mm). The time spent on the recording technique influenced the results (ANOVA: α < 0.001; F = 21.118). The IOGA (340.40 ± 163.41 s) and EOGA (285.93 ± 133.84 s) required more time compared to the D (86.00 ± 34.33 s) and FMTE (101.33 ± 36.72 s) techniques. CONCLUSION: Graphic recordings showed better reproducibility and accuracy of the position of the centric relation.


Assuntos
Boca Edêntula , Humanos , Relação Central , Registro da Relação Maxilomandibular/métodos , Reprodutibilidade dos Testes , Estudos Transversais , Côndilo Mandibular
7.
Antibiotics (Basel) ; 11(11)2022 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-36358141

RESUMO

Irritation and biofilm adhesion are complaints associated with ocular prosthesis use. This study aimed to evaluate the effects of prosthesis repolishing on several conditions of anophthalmic volunteers. Participants were divided into two groups: intervention (IG, n = 10) and nonintervention (NIG, n = 6) groups. The anophthalmic cavity, contralateral eye, and prosthesis surface were evaluated at initial, day 15, and day 30 after repolishing. Microbiological analysis (colony-forming units), exfoliative cytology (conjunctiva inflammatory cells), sensory analysis (quantitative mechanical sensory test), tear production (Schirmer's test), and conjunctival inflammation (clinical evaluation) were performed. Nonparametric tests were used to compare groups in the initial period and to analyze periods for the IG (p < 0.05). More microorganisms were formed in the anophthalmic socket and prosthesis than in the contralateral eye in the initial period. For IG, the anophthalmic cavity exhibited more microorganisms and inflammatory clinical signs in the initial period than at 15 and 30 after repolishing. The prosthesis showed greater accumulations of total bacteria and Candida albicans in the initial period than at 15 and 30 days after repolishing. The anophthalmic cavity had more palpebral inflammation than the contralateral eye. In conclusion, repolishing reduced the number of microorganisms and inflammatory signs over time.

8.
Prosthet Orthot Int ; 46(3): 299-304, 2022 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-35019887

RESUMO

OBJECTIVE: This study reports a clinical case of rehabilitation of a patient who had her left little finger amputated at the mesial phalanx because of a gunshot wound. The finger prosthesis was custom- made using a silicone. CASE DESCRIPTION: This study presents a clinical case of a female patient who had her left little finger amputated at the mesial phalanx because of a gunshot wound in 2016. The patient was attended at a reference center in maxillofacial rehabilitation in the city of Brasilia, Distrito Federal, Brazil, for the manufacture of a finger prosthesis. After molding, a finger waxing was obtained using the right little finger as a template. The waxing was later adjusted on the plaster model of the affected stump. The prosthesis was manufactured with silicone and intrinsically stained with a makeup powder. A water-based adhesive and a ring were used to generate a slight compression so that the prosthesis was retained on the stump. OUTCOMES: The rehabilitation showed satisfactory levels of stability, retention, and aesthetics, and it was usable and clinically acceptable, as observed in a follow-up appointment in February 2020. CONCLUSIONS: The complete or partial reestablishment of functions performed by important structures, such as the fingers, is essential to increase the quality of life of individuals, improving their performance of daily activities. In addition, reporting on this public health problem allows scientific advancement in the area.


Assuntos
Traumatismos dos Dedos , Armas de Fogo , Ferimentos por Arma de Fogo , Desarticulação , Feminino , Traumatismos dos Dedos/reabilitação , Traumatismos dos Dedos/cirurgia , Humanos , Desenho de Prótese , Qualidade de Vida , Silicones , Ferimentos por Arma de Fogo/complicações , Ferimentos por Arma de Fogo/cirurgia
9.
Eur J Dent ; 16(2): 351-359, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34814220

RESUMO

OBJECTIVE: This study aimed to evaluate the influence of new complete dentures (CDs) and new removable partial dentures (RPDs) on oral health-related quality of life, dry mouth sensation, and anxiety level of their wearers. MATERIALS AND METHODS: In total, 20 complete edentulous patients (in both arches) that needed to be rehabilitated with new CDs, and 20 partial edentulous patients (in both arches) that needed to be rehabilitated with new RPDs, were included in this study. Each patient must wear the same pair of CDs or RPDs for more than 5 years. Oral health-related quality of life, dry mouth sensation, and level of anxiety were assessed by using the following questionnaires: Geriatric Oral Health Assessment Index (GOHAI), VAS (Visual Analog Scale) Xerostomia Questionnaire, and State-Trait Anxiety Inventory (STAI). These questionnaires were applied before oral rehabilitation (initially initial time point) and 3 months after insertion of new dentures (end time point). STATISTICAL ANALYSIS: For the results of STAI-State, STAI-Trait, and GOHAI, the Wilcoxon test was applied to compare the time points. For the results of the VAS xerostomia questionnaire, two-way repeated measures ANOVA (analysis of variance) was applied, followed by the Tukey test. The p-values lower than 0.05 were considered statistically significant. RESULTS: /CONCLUSION: For both groups, it was observed that 3 months after the insertion of new removable dentures: (1) there was an increase in oral health-related quality of life; (2) there was a reduction in anxiety (trait anxiety and state anxiety); and (3) there was a perception of greater salivation.

10.
Eur J Dent ; 16(2): 346-350, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34808688

RESUMO

OBJECTIVES: The aim of this study was to verify during facial expressions ("happy," "sad," "fearful," "angry," "surprised," and "disgusted") if: (1) there would be difference in the electromyography (EMG) of the occipitofrontalis, temporal, masseter, and sternocleidomastoid muscles on the normal side (NS) compared with the affected side (AS) (without the use of an ocular prosthesis) in individuals with unilateral absence of the eyeball, and (2) the rehabilitation with a new ocular prosthesis would affect the EMG of the muscles studied on the AS in these individuals. MATERIALS AND METHODS: Thirteen individuals, without temporomandibular disorder, with good health, with unilateral absence of the eyeball (the eye must have been removed by evisceration or enucleation), and users or nonusers of an ocular prosthesis were included. EMG of the occipitofrontalis, temporal, masseter, and sternocleidomastoid muscles was performed during rest and facial expressions ("happy," "sad," "fearful," "angry," "surprised," and "disgusted") before (T0) and 90 days after (T1) rehabilitation with a new ocular prosthesis. The analyses were performed in T0 on NS and AS (without the use of an ocular prosthesis), and in T1 on AS with the new ocular prosthesis. STATISTICAL ANALYSIS: All data were submitted to the Student's t-test with p < 0.05. RESULTS: There was no statistically significant difference comparing the AS with the NS in T0 for all muscles studied, during all facial expressions evaluated (p > 0.05). There was no statistically significant difference comparing the AS in T0 with itself in T1 for all muscles studied, during all facial expressions evaluated (p > 0.05). CONCLUSION: Eye loss did not affect the EMG of studied muscles when comparing NS with AS (without the use of an ocular prosthesis). The rehabilitation with ocular prosthesis was not capable of changing the EMG on AS.

11.
J Clin Exp Dent ; 13(9): e920-e926, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34603621

RESUMO

BACKGROUND: This study aimed to compare the masticatory efficiency, the maximum voluntary occlusal bite force (MVOBF) and the electrical activity (EMG) of masticatory muscles of practitioners of upper limb bodybuilding before and after physical activity. MATERIAL AND METHODS: Twenty healthy individuals (10 men and 10 women, age from 18 to 30 (mean of 24.7 years old) without masticatory system disorders, that regularly practice hypertrophic physical activity were submitted to the analyses of masticatory efficiency, MVOBF, and surface EMG of the temporalis and masseter muscles. The masticatory efficiency was analyzed by comminution of the artificial material (Optocal®) and a sieving method. The MVOBF was measured by a dynamometer, and EMG was evaluated during resting mandibular position, maximum voluntary clenching (MVC), and MVC with a Parafilm M tape between teeth, and free mastication of chewing gum. The analyses were made before (T0) and immediately after the performance of upper limb bodybuilding exercises (T1). The data of masticatory efficiency and MVOBF were submitted to the Student T-test, and their correlations were analyzed by the Pearson correlation test, and the EMG data were submitted to the 2-way repeated measures ANOVA, all tests with a 5% significance. RESULTS: There was a significant decrease of masticatory efficiency after the training. No statistical difference in the MVOBF and EMG was found, and there was a positive correlation between masticatory efficiency and MVOBF. CONCLUSIONS: Therefore, changes were found for masticatory efficiency only, which decreased after hypertrophic exercise. There was a positive correlation between masticatory efficiency and MVOBF. Key words:Masticatory efficiency, bite force, physical activity, electromyography.

12.
Toxicol In Vitro ; 76: 105211, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34245821

RESUMO

The study evaluated the influence of cycles and methods of an ocular prosthesis resin on cytotoxicity toward human conjunctival cells. Resins were polymerized by water bath (WB, 74 °C or 100 °C for 30 min to 9 h), microwave (MW, 1200 W, 3 to 14 min and 30 s at 0 to 720 W), or autopolymerization (AP, room temperature for 20 min ± 60 °C for 30 min). Degree of conversion (DC), cytotoxicity, level of inflammatory mediators, gene expression of different markers, and apoptosis were evaluated. Data were submitted to ANOVA and Tukey test (p < 0.05). WB with longer processing time at higher temperature had highest DC (85.6%) and higher TGF ß1-gene expression (1.39); long cycle low power MW showed lowest DC (69.6%), lower cell proliferation (85.4%, MTT), and large IL-2 release (39,297 ng/mL). AP with additional processing time showed lower cell proliferation (75.3%, Alamar Blue), and AP polymerized at room temperature showed higher CASP 9-gene expression (1.21). AP methods showed higher IL-6 release (>277 pg/mL). Short cycle medium power MW had higher IL-23 release (534.2 pg/mL). MW (long and short cycles) and AP polymerizations have triggered a more intense inflammatory response. Among methods recommended by the manufacturer, WB showed high DC and less cytotoxicity.


Assuntos
Olho Artificial , Metilmetacrilato/toxicidade , Caspase 9/genética , Linhagem Celular , Proliferação de Células , Túnica Conjuntiva/citologia , Citocinas/genética , Citocinas/metabolismo , Células Epiteliais/efeitos dos fármacos , Células Epiteliais/metabolismo , Humanos , Teste de Materiais , Metilmetacrilato/química , Micro-Ondas , Polimerização , Água/química
13.
J Prosthet Dent ; 125(5): 832.e1-832.e6, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33858660

RESUMO

STATEMENT OF PROBLEM: The use of 0.12% chlorhexidine gluconate (CHX) may damage bisacrylate composite resin interim restorations, but whether they can be protected with an application of alcohol and/or the use of a glaze is unclear. PURPOSE: The purpose of this in vitro study was to evaluate the effect of applying a 70% alcohol solution on the physical and mechanical properties of a bisacrylate composite resin, with and without the application of a light-polymerizing glaze subjected to 0.12% CHX twice a day for 7 days. MATERIAL AND METHODS: Forty specimens of an autopolymerized bisacrylate composite resin were divided into 4 groups (n=10): Group C (without alcohol, without glaze), Group G (without alcohol, with glaze), Group A (with alcohol, without glaze), and Group AG (with alcohol, with glaze). All specimens were submitted to in vitro treatment with 0.12% CHX for 7 days, and tests of color alteration (ΔE00), microhardness, roughness, and surface were performed initially and after treatment. Data were submitted to analysis of variance (ANOVA) and the Tukey HSD test (α=.05). RESULTS: Group A had the lowest mean value of ΔE00 with a significant statistical difference from Group C. The groups with alcohol presented higher microhardness mean values compared with groups without alcohol in both periods of analysis, except for the groups with glaze in the final period. Group C showed higher mean roughness values in comparison with Group A in both periods. Group AG presented higher mean roughness values than Group G. Surface energy values did not vary significantly among groups, except between Groups C and A in the final period. CONCLUSIONS: The application of alcohol optimized the properties of the autopolymerized bisacrylate composite resin analyzed, with and without the application of glaze. Overall, the use of CHX changed the microhardness and roughness when the glaze was applied.


Assuntos
Resinas Compostas , Imersão , Clorexidina/análogos & derivados , Teste de Materiais , Propriedades de Superfície
14.
Gen Dent ; 69(1): 31-36, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33350953

RESUMO

The objective of this study was to compare techniques of different methods of obtaining centric relation to verify which technique generates the greatest reproducibility of the centric relation. The PubMed/MEDLINE, Cochrane Library, SciELO, Scopus, and Web of Science databases were searched for articles published up to May 15, 2018. The search terms were combinations of "dental centric relation" with each of the following terms (individually): "reproducibility of findings"; "jaw relation record"; "chin point"; "gothic arch"; "bimanual manipulation"; "swallowing"; and "jig." The inclusion criteria included clinical studies in English that had to compare at least 2 techniques representing different methods for obtaining centric relation (based on the reproducibility of the centric relation) in individuals without temporomandibular dysfunction; and studies performed in individuals with complete or nearly complete dentition or complete edentulism. Methods (techniques) included in this study were guided methods (chin point guidance and bimanual manipulation); graphic methods (intraoral and extraoral gothic arch tracing); and physiologic methods (swallowing and tongue retrusion along the palate). A total of 1638 articles were identified. After the inclusion and exclusion criteria were applied, 7 articles were included in this review. None of the reviewed studies evaluated edentulous individuals. Two articles compared physiologic methods with guided methods; one concluded that the swallowing technique generates greater variability than guided methods, and the other concluded that there was no difference between the swallowing technique and chin point guidance. Of 5 articles comparing intraoral gothic arch tracing with guided methods, 2 showed similar results between different methods, 2 showed superior results for gothic arch tracing, and 1 showed superior results for the guided methods. Based on the guided methods and swallowing technique, it is not possible to conclude which technique can generate the greatest reproducibility of the centric relation. It is possible to suggest that in most cases intraoral gothic arch tracing is superior or equivalent when compared to guided methods.


Assuntos
Boca Edêntula , Relação Central , Humanos , Registro da Relação Maxilomandibular , Reprodutibilidade dos Testes
15.
J Adhes Dent ; 22(5): 531-538, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33073784

RESUMO

PURPOSE: To evaluate the roughness, surface energy, and the bond strength of lithium disilicate yielded by two different types of nonthermal plasma (NTP), oxygen- or argon-based, compared to the conventional method. MATERIALS AND METHODS: Ninety-three lithium disilicate (IPS e.max Press) samples were divided into 3 groups: HF (hydrofluoric acid group); ONTP (oxygen-based NTP group); ANTP (argon-based NTP group). Surface energy and roughness analyses were performed before and after surface treatment, and bond strength testing was performed before and after 5000 thermocycles. Scanning electron microscopy (SEM) was used to characterize the surface treatments. Data were submitted to ANOVA and Bonferroni's test with statistical significance set at 5%. RESULTS: The ONTP group presented the highest surface energy values, followed by ANTP and HF. In addition, the ONTP group had higher surface roughness. SEM revealed exposed lithium disilicate crystals in the HF group, but a homogeneous film coverage in both NTP groups. Regarding bond strength, ANTP presented statistically significantly higher values than the other groups before thermocycling, and statistically significantly lower values than the other groups after thermocycling. The HF and ONTP groups presented statistically similar values after thermocycling. CONCLUSION: The bond strength of resin cement to lithium disilicate obtained after oxygen-based NTP was comparable with that obtained after conventional hydrofluoric acid treatment.


Assuntos
Colagem Dentária , Cimentos de Resina , Cerâmica , Porcelana Dentária , Propriedades de Superfície
16.
Arch Oral Biol ; 117: 104822, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32592931

RESUMO

OBJECTIVE: Overcoming substantial shortcomings of soft liners as physico-chemical changes and liner-biofilm-related infections remains a challenge in the rehabilitation treatment. In this study, protective non-thermal plasma (NTP) treatments were developed on the soft liner surface to improve its surface and physico-chemical properties and to reduce fungal colonization after biofilm inhibition challenge. METHODS: Resinous liner specimens (Coe-Soft) were prepared and distributed in 3 groups according to the surface treatments: (1) untreated (control); (2) treated with sulfur hexafluoride-based NTP (SF6); and (3) treated with hexamethyldisiloxane-based NTP (HMDSO). To test the NTP stability and their protective and antimicrobial effect on the liner surface over time, the morphology, chemical composition, roughness, water contact angle, shore A hardness, sorption and solubility were evaluated before and after the specimens were exposed to dual-species biofilm of Candida albicans and Streptococcus oralis for 14 days. Colony forming units and biofilm structure were assessed. Data were submitted to ANOVA and Tukey tests (α = 0.05). RESULTS: Both treatments modified the surface morphology, increased hydrophobicity and roughness of the liner, and were effective to reduce C. albicans adhesion without affecting the commensal health-associated S. oralis. HMDSO presented chemical stability and lower hardness in both periods, whereas SF6 exhibited higher initial hardness than control and the highest sorption; contrarily, similar solubility was noted for all groups. CONCLUSION: HMDSO-based film showed improved physico-chemical properties and inhibited C. albicans biofilm. Thus, it has potential for use to control candida-related stomatitis and improve liner's stability even after being exposed to biofilm inhibition challenge.


Assuntos
Anti-Infecciosos , Biofilmes , Reembasadores de Dentadura , Gases em Plasma , Anti-Infecciosos/farmacologia , Candida albicans , Teste de Materiais , Gases em Plasma/farmacologia , Streptococcus oralis , Propriedades de Superfície
17.
J Adv Prosthodont ; 12(2): 55-60, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32377317

RESUMO

PURPOSE: The aim was to evaluate the effect of four acidic beverages on the roughness (Ra) and color change (ΔEab) of two brands of artificial teeth and a heat-polymerized acrylic resin (HPAR) for use in a prosthetic base. MATERIALS AND METHODS: All materials were divided into 5 groups, according to the used acidic beverage (artificial saliva - control, red wine, orange juice, coke-based, and lemon juice-based soft drink). The immersion process was divided into two stages: T1 - immersion in the acidic solutions for 10 minutes for 14 days; T2 - after T1, the samples were immersed in grape juice for 14 days. The Ra of the samples was evaluated in a rugosimeter and the ΔEab in a spectrophotometer, before and after the immersions. The analysis of variance of one (ΔEab) and two factors (Ra) and Tukey were performed (α=.05). RESULTS: There was a statistical difference for roughness after immersion (T1) for Trilux and Tritone teeth, regardless of the acid solution. For Trilux teeth, all acid solutions increased Ra (P<.05). For Tritone teeth, only the coke-based soft drink did not statistically change Ra. Grape juice (T2) altered Ra only of artificial teeth (P<.05). The color was changed for all materials, after T1 and T2. CONCLUSION: In general, the acidic solutions changed the Ra and ΔEab of HPAR and artificial teeth after T1. The grape juice altered the roughness only of the artificial teeth, promoting a clinically acceptable color change in the materials.

18.
J Clin Exp Dent ; 12(2): e103-e107, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32071690

RESUMO

BACKGROUND: Different ceramic surface cleaning methods have been suggested after the acid conditioning. The aim was to evaluate the effect of different protocols used to remove the remaining hydrofluoric acid on the shear bond strength (SBS) between lithium disilicate and resin cement. MATERIAL AND METHODS: Forty-four specimens of lithium disilicate (IPS e.max Press) were divided in 4 groups (n=11): group C (control, no treatment); group HF+S (5% hydrofluoric acid + silane); group HF+US+S (5% hydrofluoric acid + ultrasound cleaning + silane); group HF+PH+S (5% hydrofluoric acid + 37% phosphoric acid + silane). Scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS) were performed to characterize the surface morphology. The SBS test was performed on the resin/ceramic interface, and the failure mode was characterized. SBS values were submitted to 1-way ANOVA and the Tukey test (α=.05). The relation between surface treatment and failure modes was analyzed using the chi-squared test (α=.05). RESULTS: The surface treatment type interfered in the shear strength (p<.001) and higher SBS values were observed for the groups HF+US+S (17.87 MPa) and HF+PH+S (16.37 MPa). The surface treatment did not influence the failure mode (p=.713). No fluorsilicate salts were observed after ultrasound cleaning. CONCLUSIONS: The utilization of ultrasound cleaning was an effective procedure to remove remaining fluorsilicate salts, promoting the highest SBS values. Key words:Bond strength, ceramics, fluorsilicate, lithium disilicate, resin cement.

19.
J Clin Exp Dent ; 11(9): e807-e813, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31636873

RESUMO

BACKGROUND: The aim of this study was to evaluate the distribution of stress in complete fixed mandibular prostheses with infrastructures (IE) fabricated with different materials and techniques, under compressive force. MATERIAL AND METHODS: A model of an edentulous mandible, which received five 4x11 mm external hexagon implants between the mental foramens, was fabricated. The groups were divided into: Group I - IE in nickel-chromium with an acrylic resin occlusal coating; Group II - IE in nickel-chromium with a ceramic occlusal coating; Group III - IE milled in zirconia with a ceramic coating. For the photoelastic methodology, 70 N axial loads were applied in three regions. Photographic images were taken and analyzed according to the number of high-intensity fringes. For the strain gauge methodology, the measurement of stresses was performed in two distinct regions. The same compression tests described earlier were then performed. The registered stress values were grouped in tables and submitted to two-factor variance analysis (ANOVA) and the Tukey test with 5% significance. RESULTS: The results of the two methodologies demonstrated smaller stress values for Group I, when compared to the other groups. CONCLUSIONS: It was possible to conclude that the complete fixed prostheses, with infrastructures cast in metal and acrylic occlusal coating, demonstrated better biomechanical results. Key words:Dental implants, mandibular prosthesis implantation, biomechanics.

20.
J Investig Clin Dent ; 10(4): e12452, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31478358

RESUMO

AIM: This study aimed to investigate the adhesion of Streptococcus sanguinis to the surface of interim prostheses that were treated or not treated with a light-activated glaze, and subjected or not subjected to a thermocycling procedure. METHODS: 36 specimens of each resin were divided into 4 groups: heat-activated acrylic resin; chemically-activated acrylic resin; bis-acryl composite resin (Protemp; 3M ESPE); and bis-GMA (Charisma; Heraeus Kulzer). Half of the specimens underwent application of glaze and the other half underwent mechanical polishing. Specimens were randomly distributed into groups (N = 9) with and without thermocycling (2000 cycles). Surface energy, roughness and microbiological analyses were performed. RESULTS: Groups treated with glaze showed lower roughness when compared with the same groups without glaze treatment, before and after thermocycling, except for the bis-acryl groups after thermocycling. Surface energy values were higher in the groups treated with glaze, except the bis-acryl group before and after thermocycling. After thermocycling, the values of bacterial adhesion decreased numerically, with the exception of the chemically-activated acrylic resin group treated with glaze and the heat-activated acrylic resin group without glaze treatment. CONCLUSION: The application of glaze and the thermocycling do not influence, in a statistically significant manner, the bacterial adhesion on polymer surfaces.


Assuntos
Resinas Compostas , Polímeros , Bis-Fenol A-Glicidil Metacrilato , Teste de Materiais , Próteses e Implantes , Streptococcus , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...